| Characteristics | Value |
| Flash rate control | Internally: by manual adjustment
Externally: by electric pulses or available sensors |
| Functions | Phase shifter (electronic shifting of the observation position)
Slow motion control
|
| Flash range | 0 ... 6.000 flashes/min or 0 ... 100 flashes/s |
| Power supply | 24 V DC from separate power supply unit for 100 … 240 V mains supply |
| Dimensions | W=198 mm, H=75 mm, D=100 mm |
| Supplements | Photoelectric sensors and proximity detectors for external control |
| Options | Extended flash frequency up to 30.000 flashes/min.
UV-light
Modifiable cable lengths for lamps and external sensors.
Rotary encoder for manual adjustment of the flash frequency and electronic image shifting integrated in the supply unit |